In this blog, we will discuss the topic of why is my AC
running but not cooling and how do you can fix AC issues. In a properly working
air-conditioner, the fan will pull air from the evaporator coils and then
circulate back in the room.
If the filter is clogged, then also your ac might not work
efficiently and will restrict the airflow.
This will result in no air being circulated in the room.
It
is necessary to clean the filter as often as possible. If the evaporator coils
are dirty then you need to clean it with detergent and brush.
Here, Doorstephomerepairs has mentioned in detail reasons
and solution of why you’re AC doesn’t blow cold air and if you want to know
more about other AC issues and solution or need doorstep service of ac repair in Noida then you can visit
our website.
Fan Motor
- If the air conditioner doesn’t blow cold air, the problem can be a fan or a fan motor.
- In an efficiently working air-conditioner, the fan will draw air from the evaporator coils and re-circulate the air back into the room.
- If the circulating fan is too slow, no air will be passed through the evaporator coils and this makes the ac to freeze and restrict the airflow further.
- Fan and motor need to be removed to carry on the check it. The technicians will monitor the fan motor and ensure that the fan motor blades are not damaged when seizing it off.
- If the motor is damaged, it needs to be replaced.
- If the motor moves easily, it may be defective. The technician will perform certain tests and will check the hidden reason behind it.
Temperature Control
- If the air-conditioner is not blowing air and you have inspected the clogged filter
and fan motor and have found them okay, then there may be a problem of
temperature control or it could be due to the faulty thermostat.
- This is the device
that monitors the incoming air and turns off the compressor.
- There is a bulb
attached to it and it will extend to the evaporator coil and electrical
circuits that supply power.
- The bulb will monitor
the room temperature and will indicate the thermostat the compressor to turn on
if the set temperature is lower than the room temperature.
- If the thermostat is
defective, it might not send signals to the compressor and hence this might be
the reason why the AC is not blowing cold air.
- The technician will
inspect the bulb, or any bend, rupture and replace the same.
Electronic Control
Board
- If you have checked
the filter, motor, thermostat and it is not blowing cold air, then there might
be a problem with Control Board, sometimes known as PCB.
- The control board
should work in conjunction with a thermostat that monitors incoming air
temperature and switch on and off the compressor depending upon the outside
temperature.
- The thermostat
connected to the control board might be defective, it might not send power
signals to the compressor, and hence there is no cooling.
- The technician will
inspect the thermostat and check if there is any damage or corrosion.
Circuit Breaker
- If the air-conditioner isn’t able to blow cold air, it may be due to the faulty
compressor circuit. Most of the air-conditioners use a capacitor to start the
compressor.
- If the capacitor is
not able to start the fan, it will blow warm air.
- Some window
air-conditioners work in conjunction with the capacitor and fan motor circuit
to blow air. To check this default, you need a qualified person.
- If the technician
asks you to replace the capacitor check the specifications. It should be
original.
Thermostat
- If the
air-conditioner isn’t blowing cold air and you have inspected the filter, fan
motor, capacitor, and found them okay, then there may be a problem with the
thermostat.
- This is a component
seen in the electronic control board and it monitors the incoming air
temperature and indicates the main control board to switch on and off the
compressor.
- The device is located
near the evaporator coil. If you have found a thermostat defective, you need to
call the technician.
- If it is defective,
it will not provide a clear signal to the control board and you won’t be able
to turn on the compressor circuit.
- The professional
might ask you to replace the same if he sees any signs of damage or corrosion.
Low Refrigerant Level
- Contrary to the
popular perception, the coolant doesn’t deplete, the reason behind it is
refrigerant leakage.
- Slow leaks in the
refrigerant level drops with time and there is a need for proper monitoring.
- This should be done
by the professionals due to the complex nature of the ac and chemicals involved
in it.
- Depending upon the age of the unit and level of technicality, consider updating the ac. An upgrade is a better decision if
•
The System is more
then 10 years old
•
The System is
experiencing a problem
•
If the cost is too
high
It's great to be here with everyone, I have a lot of knowledge from what you share, to say thanks, the information and knowledge here helps me a lot.
ReplyDeleteIf Want Play online Satta King Game Click SattaKing :-
Thanks for the informative and helpful post, obviously in your blog everything is good..
ReplyDeleteAC Service Near Me
AC Mechanic Near Me
AC Shifting
AC on Rent in Delhi
AC AMC